The primary function of a desuperheater is to lower the temperature of superheated steam or other vapors. This temperature reduction is accomplished as a result of the process vapor being brought into direct contact with another liquid such as water. The injected water is then evaporated.
Table of Contents
What is the function of a steam desuperheater?
The primary function of a desuperheater is to lower the temperature of superheated steam or other vapors. This temperature reduction is accomplished as a result of the process vapor being brought into direct contact with another liquid such as water. The injected water is then evaporated.

What is a steam Attemperator?
Attemperator Desuperheaters reduce the steam temperature by combining the superheated steam with water. The steam is cooled through the evaporation of the water. The flow control of water is critical to ensure the correct temperature and pressure are achieved.
What is a desuperheater?
The hot water generating component of a geothermal system is called a desuperheater. It is merely a pump and a heat exchanger that is plumbed in such a way so as to carry the waste heat away from the refrigeration cycle and into your water heater.
What is a desuperheater valve?
A desuperheater injects a controlled, predetermined amount of water into a steam flow to lower the temperature of the steam. To achieve this efficiently, the desuperheater must be designed and selected correctly for the application.

What is the difference between Attemperator and desuperheater?
An attemporator controls the steam temperature while a desuperheater removes whatever superheat there is in steam and reduces the temperature to a point at or nearly at saturation temperature.
How much does a desuperheater cost?
The Desuperheater Pump is USD195. 00 and the cost for the Desuperheater option is USD425.
What is a desuperheater HVAC?
Desuperheaters, or recuperaters, operate by utilizing the high-pressure, superheated discharge gas temperature to heat water. The cooling of the discharge gas normally represents 15-25% of the total heat of rejection.
What is the purpose of Attemperators and desuperheater in a boiler?
In this case, the desuperheater is often referred to as an attemperator. It is named an attemperator because it tempers the high steam temperature to an accurate temperature. Functionally, a desuperheater and attemperator are the same, i.e. they remove the superheat content of the steam with the help of water.
What is a spray desuperheater?
In water spray desuperheaters, superheated steam is passed through a section of pipe fitted with one or more spray nozzles. These inject a fine spray of cooling water into the superheated steam, which causes the water to be converted into steam, reducing the quantity of superheat.
How deep do you dig for geothermal heating?
It requires trenches at least four feet deep. The most common layouts either use two pipes, one buried at six feet, and the other at four feet, or two pipes placed side-by-side at five feet in the ground in a two-foot wide trench.
Does desuperheater work in winter?
A desuperheater works in winter too. It’s not quite as efficient as in summer, since you need all the heat you can get when the temperature gets cold. Despite that, it’s still a useful addition as it benefits from geothermal efficiencies rather than electric heating inefficiencies.
What is chiller desuperheater?
Superheat is a measured value. It is the difference between two temperatures. Superheat is measured as the difference between the actual temperature of the refrigerant vapor and the saturation temperature of the refrigerant at that same point.
Why Desuperheating is done?
Desuperheaters are used in boilers to reduce the temperature of the superheated steam that is produced in the superheater for electricity generation. The desuperheater helps in lowering the high temperature of the steam to low temperatures that will help in safely carryout the other process operation.
What is a good superheat?
Superheat for most systems should be approximately 10F measured at the evaporator; 20°F to 25°F near the compressor.
What is a good superheat for 410a?
Most heating and cooling systems should operate at a superheat of 10F at the evaporator and between 20F to 25F at the compressor. if your HVAC system has a thermostatic expansion valve (TXV), the subcooling should be between 10F and 18F.
How deep do you have to dig for geothermal energy?
How deep do you have to dig? For a horizontal loop you only need to dig between 6 – 8 feet deep. For a vertical loop you need to drill between 250 and 300 feet deep.